ISO 9001 Certified

Insulated Positive Pipe Anchor

C4200

Load Rating600–16,500 lbs
Pipe Sizes1" – 42" IPS

Talk to a pipe support specialist about your application.

1-707-447-5014

General Dimensions & Specifications


Model C4200 Insulated Positive Pipe Anchor

Models C4200, C4210, C4220, C4230. Base Mounted.
C4200 dimensional drawing

The load ratings represent average values obtained in accordance with accepted
test methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thicknesses.

If thrust plate thickness “D” is greater than pipe wall thickness, consult factory.

Note: For higher load ratings, see C4300.

Pipe
Size
Load Rating (lbs) Insulation Thickness
Vert. Lat. Axial 2″ 2 1/2″ 3″ 4″
B C D E B C D E B C D E B C D E
1 600 300 900 4 3 0.3125 6.687 4 4 0.3125 7.75 6 4.5 0.3125 8.75 6 6.5 0.3125 10.75
1 1/2 870 435 1290 4 4 0.3125 7.75 4 4.5 0.3125 8.75 6 5.5 0.375 9.75 6 7.5 0.375 11.875
2 1090 545 1620 4 4 0.3125 7.75 4 4.5 0.3125 8.75 6 5.5 0.375 9.75 6 7.5 0.375 11.875
2 1/2 1310 655 1960 4 4.5 0.3125 8.75 4 5.5 0.375 9.75 6 6.5 0.375 10.75 6 8 0.375 12.875
3 1600 800 3450 4 4.5 0.375 8.75 4 5.5 0.5 9.75 6 6.5 0.5 10.75 6 8 0.5 12.875
4 2500 1250 4100 4 5.5 0.375 9.75 4 6.5 0.5 10.75 6 7.5 0.5 11.875 6 9 0.5 13.875
5 3100 1550 4750 4 6.5 0.375 10.75 4 7.5 0.5 11.875 6 8 0.5 12.875 6 9.5 0.5 15.125
6 3800 1900 5400 4 7.5 0.375 11.875 4 8 0.5 12.875 6 9 0.5 13.875 6 10.5 0.5 16.125
8 5100 2550 6675 4 9 0.375 13.875 6 9.5 0.5 15.125 6 10.5 0.5 16.125 6 12 0.5 18.125
10 6000 3000 8000 4 10.5 0.375 16.375 6 11 0.5 17.375 6 12 0.5 18.375 6 13 0.5 20.375
12 6600 3300 9300 4 12 0.375 18.375 6 12.5 0.5 19.375 6 13 0.5 20.375 6 14.5 0.5 22.375
14 7500 3750 10000 4 12.5 0.375 19.375 6 13 0.5 20.375 6 14 0.5 21.375 6 15.5 0.5 23.375
16 8700 4350 11300 6 14 0.375 21.375 6 14.5 0.5 22.375 6 15.5 0.5 23.375 8 16.5 0.5 25.375
18 9600 4800 12500 6 15.5 0.375 23.375 6 16 0.5 24.375 6 16.5 0.5 25.375 8 18 0.5 27.375
20 10200 5100 13800 6 16.5 0.375 25.375 6 17.5 0.5 26.375 6 18 0.5 27.375 8 19.5 0.5 29.375
24 10800 5400 16300 6 19.5 0.375 29.375 6 20.5 0.5 30.375 6 21 0.5 31.375 8 22.5 0.5 33.375
30 14100 7050 20100 6 24 0.375 35.625 6 24.5 0.5 36.625 6 25 0.5 37.625 8 26.5 0.5 39.625
36 16500 8250 23900 6 28 0.375 41.625 6 28.5 0.5 42.625 6 29.5 0.5 43.625 8 31 0.5 45.625
42 16500 8250 23900 6 32.5 0.375 47.625 6 33 0.5 48.625 6 33.5 0.5 49.625 8 35 0.5 51.625
All dimensions in inches. “B”, “C”, “D” and “E” refer to the drawing above.

Application

Models C4200 through C4230 are designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Where large axial forces must be resisted
  • Steam
  • Air
  • Gas
  • Vacuum

Intended for installation on:

  • Flat surfaces

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., C4200U)

Features

  • All pipe sizes
  • Positive stop – axial, lateral, vertical
  • Bottom-of-pipe to top-of-steel matches insulated supports in “B” series
  • Easy installation
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
Performance test results on file – available upon request.

Material Data

C4200 – C4230 Spec Doc Specification document: No. 209
Thrust Plates Steel inner thrust plates (supplied loose):
C4200: ASTM A36, for Carbon Steel pipe
C4210: ASTM A387 Gr. 22, for Chrome-Moly pipe
C4220: ASTM A515 Gr. 70, for Carbon Silicon pipe
C4230: ASTM A304L, for Stainless Steel pipe
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Steel Straps & Base Carbon steel, ASTM A-36
Glue Industrial contact adhesive
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model C4200U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Model C4200 is designed for use on:

  • Cold Water
  • Hot Water
  • Dual Temperature
  • Chilled Water
  • Vacuum
  • Steam
  • Gas
  • Air
  • Where large axial forces must be resisted

Intended for Installation on:

  • Flat Surfaces

Temperature Range:

  • Standard: +40°F to +1200°F CalSil Insulation
    Note: Up to 1800°F available upon request.
  • Cryogenic: -275°F to +275°F Urethane Insulation.
    Add U after the model number (i.e., C4200U)

Insulation Thickness Table

Pipe SizeLoad RatingInsul Thk. = 2"Insul Thk. = 2-1/2"Insul Thk. = 3"Insul Thk. = 4"
Vert. lb.Axial lb.BCDEBCDEBCDEBCDE
1600900430.31256.687440.31257.7564.50.31258.7566.50.312510.75
1 1/28701290440.31257.7544.50.31258.7565.50.3759.7567.50.37511.875
210901620440.31257.7544.50.31258.7565.50.3759.7567.50.37511.875
2 1/21310196044.50.31258.7545.50.3759.7566.50.37510.75680.37512.875
31600345044.50.3758.7545.50.59.7566.50.510.75680.512.875
42500410045.50.3759.7546.50.510.7567.50.511.875690.513.875
53100475046.50.37510.7547.50.511.875680.512.87569.50.515.125
63800540047.50.37511.875480.512.875690.513.875610.50.516.125
851006675490.37513.87569.50.515.125610.50.516.1256120.518.125
1060008000410.50.37516.3756110.517.3756120.518.3756130.520.375
12660093004120.37518.375612.50.519.3756130.520.375614.50.522.375
14750010000412.50.37519.3756130.520.3756140.521.375615.50.523.375
168700113006140.37521.375614.50.522.375615.50.523.375816.50.525.375
18960012500615.50.37523.3756160.524.375616.50.525.3758180.527.375
201020013800616.50.37525.375617.50.526.3756180.527.375819.50.529.375
241080016300619.50.37529.375620.50.530.3756210.531.375822.50.533.375
3014100201006240.37535.625624.50.536.6256250.537.625826.50.539.625
3616500239006280.37541.625628.50.542.625629.50.543.6258310.545.625
421650023900632.50.37547.6256330.548.625633.50.549.6258350.551.625

Installation Guide

Installation Model A1000 - A4000 & A9000

Model A1000 – A4000 & A9000

1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.

2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.

Installation Model A5000 - A8400

Model A5000 – A8400

1. When used on a flat surface, position shield so that it is centered on the structural steel.

2. When used with a clevis hanger, position shield symmetrically.

3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.

Completed assembly without load plate

Completed Assembly Without Load Plate

Completed assembly with load plate

Completed Assembly With Load Plate

Downloads & resources

Form
Custom Design Request

Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.

Start Request →
RFA
Revit RFA 3D Model

A1000 Insulated Pipe Support Revit RFA model for BIM & coordination workflows.

Download 3D Model →
Meet
Schedule a Meeting

Talk through your application with a Pipe Shields engineer.

Book a Time →
Top