Insulated Pipe Support – With Load Distribution Plate – A5000

Insulated Pipe Support - With Load Distribution Plate - A5000 - Details

Download 3D Models

Custom Design Request

Request a Quote


General Dimensions & Specifications

Download PDF

Model A5000 Insulated Pipe Support
Section View
A5000 Dimensions

Hardware sold separately

Note: For higher load ratings, see A7000

Oper.
Temp.
°F
Mult.
Factor
“F”
500 0.90
750 0.75
1000 0.50
1200 0.30
TABLE II

Pipe
Size
MAXIMUM LOAD
RATING (LBS)
A B C Max. Axial
Travel
(inches)
on
Pipe Roll
+/-
On Flat
Surface
(a) (b)
On Pipe
Roll
(b)
2 1/2 200 180 9 6 1/4 2
3 250 225 9 6 1/4 2
3 1/2 300 270 9 6 1/4 2
4 350 315 9 6 1/4 2
5 450 400 9 6 1/4 2
6 500 450 9 6 1/4 2
8 625 550 9 6 1/4 2
10 650 575 9 6 1/4 2
12 925 825 12 9 3/8 3
14 1000 900 12 9 3/8 3
16 1100 975 12 9 1/2 3
18 1200 1075 12 9 1/2 3
20 1300 1150 12 9 1/2 3
24 1400 1250 12 9 3/4 3
30 1500 1350 12 9 3/4 3
36 1500 1350 12 9 3/4 3
42 1500 1350 12 9 3/4 3
TABLE I

Contact factory for other dimensions, temperatures, and loads.
Available in all insulation thicknesses.

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice. Contact factory for current information.

a) To develop maximum load rating, width of support surface should be at least 1/2 of dimension “B” in Table I.

b) To obtain load ratings for operating temperatures of 500°F and higher, multiply maximum load rating by factor “F” in Table II.

Application:

Model A5000 is designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Steam
  • Air
  • Gas
  • Vacuum

Intended for installation on:

  • Flat surfaces
  • Pipe rolls

Temperature Range:

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., A5000U)

Features:

  • Compact
  • Easy installation
  • Eliminates welding to pipe
  • Copper tubing sizes available
  • Overlapping galvanized sheet metal jacket
  • Minimizes heat loss and/or condensation
  • Load distribution plate integral with bottom jacket
  • Other I.D.’s and/or O.D.’s available on request

Performance test results on file:
Available upon request

Material Data:

  • A5000:
    Applicable PSI spec. doc.: No. 205
  • Insulation:
    Calcium silicate asbestos-free,
    treated with water repellant
  • Jackets:
    Galvanized steel ASTM A-653
  • Load distribution Plate:
    Carbon steel ASTM A-36
  • Coating:
    Primer coated or hot-dip galvanized
    Other coatings available upon request
  • Glue:
    Industrial contact adhesive


Formal submittal sheets available

Top