ISO 9001 Certified

Insulated 2-Bolt Hanger

D3000

Load Rating285–7,970 lbs
Pipe Sizes1" – 42" IPS

Talk to a pipe support specialist about your application.

1-707-447-5014

General Dimensions & Specifications


Model D3000 Insulated 2-Bolt Hanger

Hung from threaded rod.
D3000 dimensional drawing

The load ratings represent average values obtained in accordance with accepted test
methods and are subject to normal manufacturing variations. Dimensions and ratings are
subject to change without notice. Available in all insulation thicknesses.

Contact factory for current information.

Note: For higher load ratings, see D3100.

Iron
Pipe
Size
Vert.
Load
(lbs)
A B C D Insulation Thickness
1″ 2″ 3″ 4″ 5″
E F E F E F E F E F
1 285 3/16 x 2 0.375 0.675 0.75 2.81 6 3.84 6 4.88 6 5.88 6 6.94 6
1 1/2 320 3/16 x 2 0.375 0.675 0.75 3.06 6 4.38 6 5.38 6 6.44 6 7.44 6
2 320 3/16 x 2 0.375 0.675 0.75 3.31 6 4.38 6 5.38 6 6.44 6 7.44 6
2 1/2 540 1/4 x 2 0.375 0.675 0.75 3.69 6 5 6 6 6 7.06 6 8.19 6
3 540 1/4 x 2 0.375 0.675 0.75 3.97 6 5 6 6 6 7.06 6 8.19 6
4 770 1/4 x 3 0.5 0.84 0.75 4.63 6 5.63 6 6.69 6 7.69 6 8.81 6
5 1125 3/8 x 3 0.5 0.84 0.75 5.38 6 6.38 6 7.44 6 8.56 6 9.56 6
6 1430 3/8 x 3 0.625 1.05 0.75 6 6 7.06 6 8.06 6 9.18 6 10.19 6
8 1805 1/2 x 3 0.625 1.05 0.75 7.31 6 8.31 6 9.44 6 10.44 6 11.44 6
10 2310 1/2 x 3 0.75 1.05 0.75 8.44 6 9.56 6 10.56 6 11.56 6 12.56 6
12 2705 5/8 x 3 0.75 1.05 0.75 9.69 6 10.69 6 11.69 6 12.69 6 13.69 6
14 2705 5/8 x 3 0.75 1.05 0.75 10.19 6 11.19 6 12.18 6 13.19 6 14.19 6
16 3035 5/8 x 3 0.875 1.315 1 11.31 6 12.31 6 13.31 6 14.31 6 15.31 6
18 3750 3/4 x 3 0.875 1.315 1 12.56 6 13.56 6 14.56 6 15.56 6 16.56 6
20 3855 3/4 x 3 1 1.315 1 13.69 6 14.69 6 15.69 6 16.69 6 17.69 6
24 4935 1 x 3 1 1.315 1 16.19 6 17.19 6 18.19 6 19.18 6 20.19 6
30 5295 1 x 3 1.25 1.66 1.25 19.44 6 20.44 6 21.44 6 22.44 6 23.44 6
36 7855 1 x 6 1.25 1.66 1.25 22.44 9 23.44 9 24.44 9 25.44 9 26.44 9
42 7970 1 x 6 1.25 1.66 1.25 25.44 9 26.44 9 27.44 9 28.44 9 29.44 9
TABLE I   All dimensions in inches. “A” through “F” refer to the drawing above.

Application

D3000 is designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Steam
  • Air
  • Gas
  • Vacuum

Intended to be hung from threaded rod.

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., D3000U)

Features

  • Compact
  • Eliminates welding to pipe
  • Copper tubing sizes and pipe sizes
  • Minimizes heat loss and/or condensation
  • Easy installation
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
Performance test results on file – available upon request.

Material Data

D3000 Spec Doc Applicable PSI spec. doc.: No. 209
Insulation Calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Glue Industrial contact adhesive
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Steel Straps Carbon steel, ASTM A-36
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model D3000U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Installation Guide

Installation Model A1000 - A4000 & A9000

Model A1000 – A4000 & A9000

1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.

2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.

Installation Model A5000 - A8400

Model A5000 – A8400

1. When used on a flat surface, position shield so that it is centered on the structural steel.

2. When used with a clevis hanger, position shield symmetrically.

3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.

Completed assembly without load plate

Completed Assembly Without Load Plate

Completed assembly with load plate

Completed Assembly With Load Plate

Downloads & resources

Form
Custom Design Request

Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.

Start Request →
RFA
Revit RFA 3D Model

A1000 Insulated Pipe Support Revit RFA model for BIM & coordination workflows.

Download 3D Model →
Meet
Schedule a Meeting

Talk through your application with a Pipe Shields engineer.

Book a Time →
Top