Insulated Pipe Riser Clamps for Upward or Downward Loads – E2100

Insulated Pipe Riser Clamps for Upward or Downward Loads - E2100 - Details

Download 3D Models

Custom Design Request

Request A Quote


General Dimensions & Specifications


Model E2100 Insulated Pipe Riser Clamp for Upward or Downward Loads

Models E2100, E2110, E2120, E2130.
E2100 dimensional drawing

  • Type: Insulated riser clamp, upward or downward loads
  • B = thrust plate thickness (a)
  • C = clamp bar size (thickness x width)
  • A, D through H as shown on drawing

a) If thrust plate thickness “B” is greater than pipe wall thickness, consult factory.

b) Two pair thrust plates supplied loose for field welding, top and bottom.

Available in all insulation thicknesses.

Note: For higher load ratings, see E2200.

Pipe
Size
Vert.
Load
(lbs)
A B C D E Insulation Thickness
1″ 2″ 3″ 4″
F G H F G H F G H F G H
2 500 0.63 0.38 0.38 x 3.00 1.50 0.625 3.94 6.19 5.38 5.00 7.25 7.50 6.00 8.25 9.50 7.06 9.31 11.63
2 1/2 600 0.63 0.38 0.38 x 3.00 1.50 0.625 4.19 6.44 5.88 5.50 7.75 8.50 6.50 8.75 10.50 7.56 9.81 12.63
3 800 0.63 0.38 0.38 x 3.00 1.50 0.625 4.47 6.72 6.44 5.50 7.75 8.50 6.50 8.75 10.50 7.56 9.81 12.63
4 1200 0.63 0.38 0.38 x 3.00 1.50 0.625 5.00 7.25 7.50 6.00 8.25 9.50 7.06 9.31 11.63 8.06 10.31 13.63
5 1600 0.63 0.38 0.38 x 4.00 2.00 0.625 5.50 7.75 8.50 6.50 8.75 10.50 7.56 9.81 12.63 8.69 10.94 14.88
6 2000 0.63 0.38 0.38 x 4.00 2.00 0.625 6.00 8.25 9.50 7.06 9.31 11.63 8.06 10.31 13.63 9.19 11.44 15.88
8 2600 0.63 0.50 0.50 x 4.00 2.00 0.625 7.31 9.81 11.88 8.31 10.81 13.88 9.44 11.94 16.13 10.44 12.94 18.13
10 3200 0.88 0.50 0.50 x 5.00 3.00 0.625 8.31 10.81 13.88 9.44 11.94 16.13 10.44 12.94 18.13 11.44 13.94 20.13
12 3400 0.88 0.50 0.50 x 5.00 3.00 0.625 9.44 11.94 16.13 10.44 12.94 18.13 11.44 13.94 20.13 12.44 14.94 22.13
14 4000 0.88 0.50 0.50 x 5.00 3.00 0.75 10.06 12.69 17.13 11.06 13.69 19.13 12.06 14.69 21.13 13.06 15.69 23.13
16 4600 0.88 0.50 0.50 x 6.00 4.00 0.75 11.06 13.69 19.13 12.06 14.69 21.13 13.06 15.69 23.13 14.06 16.69 25.13
18 5000 0.88 0.50 0.50 x 6.00 4.00 0.75 12.06 14.69 21.13 13.06 15.69 23.13 14.06 16.69 25.13 15.06 17.69 27.13
20 5400 0.88 0.50 0.50 x 6.00 4.00 0.75 13.06 15.69 23.13 14.06 16.69 25.13 15.06 17.69 27.13 16.06 18.69 29.13
24 5600 0.88 0.50 0.50 x 6.00 4.00 0.75 15.06 17.69 27.13 16.06 18.69 29.13 17.06 19.69 31.13 18.06 20.69 33.13
All dimensions in inches. “A” through “H” refer to the drawing above.

Models E2100 through E2130 are designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Steam
  • Air
  • Gas
  • Vacuum

Intended for installation on:

  • Vertical runs of insulated pipe with upward and/or downward load

Other:

  • For handling downward loads only, see E1200

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., E2100U)

  • All pipe sizes
  • Positive stop – axially upward or downward
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
  • Easy installation
  • May be supported from below or above
  • Insulating structural inserts for load transfer
  • Eliminates condensation sweating on chilled water risers
Performance test results on file – available upon request.
E2100 – E2130 Spec Doc Specification document: No. 206
Thrust Plates Steel inner thrust plates (supplied loose):
E2100: ASTM A36, for Carbon Steel pipe
E2110: ASTM A387 Gr. 22, for Chrome-Moly pipe
E2120: ASTM A515 Gr. 70, for Carbon Silicon pipe
E2130: ASTM A304L, for Stainless Steel pipe
Insulation Calcium silicate, asbestos-free, treated with water repellant
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Steel Straps & Base Carbon steel, ASTM A-36
Glue Industrial contact adhesive
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model E2100U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Iron Pipe Sizeload lb.ABCDEInsul Thk. = 1"Insul Thk. = 2"Insul Thk. = 3"Insul Thk. = 4"
FGHFGHFGHFGH
25000.630.380.38 x 3.001.50.6253.946.195.3857.257.568.259.57.069.3111.63
2 1/26000.630.380.38 x 3.001.50.6254.196.445.885.57.758.56.58.7510.57.569.8112.63
38000.630.380.38 x 3.001.50.6254.476.726.445.57.758.56.58.7510.57.569.8112.63
412000.630.380.38 x 3.001.50.62557.257.568.259.57.069.3111.638.0610.3113.63
516000.630.380.38 x 4.0020.6255.57.758.56.58.7510.57.569.8112.638.6910.9414.88
620000.630.380.38 x 4.0020.62568.259.57.069.3111.638.0610.3113.639.1911.4415.88
826000.630.50.50 x 4.0020.6257.319.8111.888.3110.8113.889.4411.9416.1310.4412.9418.13
1032000.880.50.50 x 5.0030.6258.3110.8113.889.4411.9416.1310.4412.9418.1311.4413.9420.13
1234000.880.50.50 x 5.0030.6259.4411.9416.1310.4412.9418.1311.4413.9420.1312.4414.9422.13
1440000.880.50.50 x 5.0030.7510.0612.6917.1311.0613.6919.1312.0614.6921.1313.0615.6923.13
1646000.880.50.50 x 6.0040.7511.0613.6919.1312.0614.6921.1813.0615.6923.1314.0616.6925.13
1850000.880.50.50 x 6.0040.7512.0614.6921.1313.0615.6923.1314.0616.6925.1315.0617.6927.13
2054000.880.50.50 x 6.0040.7513.0615.6923.1314.0616.6925.1315.0617.6927.1316.0618.6929.13
2456000.880.50.50 x 6.0040.7515.0617.6927.1316.0618.6929.1317.0619.6931.1318.0620.6933.13
Top