Insulated Pipe Support – Regular Duty with Extended Insulation – A2000

INSULATED PIPE SUPPORT - REGULAR DUTY WITH EXTENDED INSULATION - A2000 - DETAILS

Download 3D Models

Custom Design Request

REQUEST A QUOTE


General Dimensions & Specifications

A2000 insulated pipe support

A2000 assembly

Hardware sold separately.
Note: For higher load ratings, see A4000, A9000.

Cross section

Dimension A

Oper.
Temp.
°F
Mult.
Factor
“F”
500 0.90
750 0.75
1000 0.50
1200 0.30
TABLE III
Pipe
Size
MAXIMUM LOAD
RATING (LBS)
On Flat
Surface
(a) (c)
In Clevis
Hanger
(b) (c)
1/2 35 40
3/4 40 45
1 60 65
1 1/4 70 80
1 1/2 100 110
2 125 140
2 1/2 150 200
3 180 250
3 1/2 225 300
4 270 350
5 350 450
6 400 550
8 450 750
10 500 1000
12 550 1200
14 575 1400
16 600 1600
18 625 1800
20 675 2000
24 750 2300
TABLE I

Contact factory for other dimensions,
temperatures, and loads.

Available in all insulation thicknesses.

The load ratings represent average values obtained in accordance with accepted
methods and are subject to normal manufacturing variations. Dimensions and ratings
are subject to change without notice.

a) To develop maximum load rating, width of support surface should be at least 1/2 of dimension “A” in Table II.

b) To develop maximum load rating, use band, ring or clevis hanger with manufacturer’s load rating equal to or greater than values shown in Table I.

c) To obtain load ratings for operating temperatures of 500° F and higher, multiply load rating by factor “F” in Table III.

Iron
Pipe
Size
Insulation Thickness Copper
Tubing
Size O.D.
1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4
A B A B A B A B A B A B A B A B A B
1/2 – 1 1/2 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 5/8 – 1 5/8
2 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/8
2 1/2 – 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 – 4 1/8
5 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/8
6 – 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/8
8 – 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 – 10 1/8
12 – 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/8
20 – 24 18 16 18 16 18 16 18 16 18 16 18 16
TABLE II   “B” = gauge of sheet metal jacket

Application:


Model A2000

is designed for use on:
Cold water
Chilled water


Intended for installation on:
Flat surfaces
Band, ring or clevis pipe hanger


Temperature Range:

Standard: +40°F to +1200°F CalSil Insulation
Note: Up to 1800°F available upon request.
Cryogenic: -275°F to +275°F Urethane Insulation.
Add U after the model number (i.e., A2000U)

Features:

  • Compact
  • Easy installation
  • Eliminates welding to pipe
  • Overlapping galvanized sheet metal jacket
  • Minimizes heat loss and/or condensation
  • Calcium silicate insulation extends 1” beyond the galvanized sheet metal jacket providing for an easier vapor barrier joint with the pipe insulation
  • Copper tubing sizes available
  • Other I.D.’s and/or O.D.’s available on request
  • Clamps available (see G-series)
  • Clevis available (see PTP fig. 83)

Performance test results on file:

 

Available upon request.

Material Data:

  • A2000:
    Applicable PSI spec. doc.: No. 205
  • Insulation:
    Calcium silicate asbestos-free, treated with water repellant
  • Jackets:
    Galvanized steel ASTM A-653
  • Glue:
    Industrial contact adhesive


Formal submittal sheets available.