Insulated Pipe Support – Heavy Duty for Use with Rod Hangers – A9000

Insulated Pipe Support - Heavy Duty for Use with Rod Hangers - A9000 - Details

Download 3D Models

Custom Design Request

Request A Quote


General Dimensions & Specifications

Model A9000 Insulated Pipe Support

Hardware sold separately
Note: For higher load ratings, see B1200

Section View
A5000 Dimensions

Pipe
Size
MAXIMUM
LOAD RTG.
(LBS)In Ring
or Clevis
Hanger
(a)
1/2 50
3/4 55
1 80
1 1/4 100
1 1/2 130
2 175
2 1/2 250
3 300
3 1/2 350
4 400
5 550
6 600
8 900
10 1200
12 1450
14 1650
16 1900
18 2150
20 2400
24 2750
TABLE I

Contact factory for other dimensions, temperatures, and loads. Available in all insulation thicknesses.

The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice.

a) To develop maximum load rating use band, ring or clevis hanger with manufacturer’s load rating equal to or greater than values shown in Table I

Iron
Pipe
Size
Insulation Thickness Copper
Tubing
Size O.D.
1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4
A B A B A B A B A B A B A B A B A B
1/2 – 1 1/2 4 24 4 24 4 24 4 24 4 24 4 24 6 24 6 24 6 24 5/8-1 5/8
2 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/8
2 1/2 – 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 – 4 1/8
5 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/8
6 – 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/8
8 – 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/8
12 – 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/8
20 – 24 18 16 18 16 18 16 18 16 18 16 18 16
TABLE II   “B” = gauge of sheet metal jacket    (bottom jacket approx. 2 X ga. of top jacket)

Application:

Model A9000 is designed for use on:

  • Hot water | Steam
  • Cold water  | Air
  • Chilled water | Gas
  • Dual temperature | Vacuum

Intended for installation on:

  • Band, ring or clevis pipe hangers
  • Flat surfaces, see A7000
  • Pipe rolls, see A8000

Temperature Range:

Standard: +40°F to +1200°F CalSil Insulation
Note: Up to 1800°F available upon request.
Cryogenic: -275°F to +275°F Urethane Insulation.
Add U after the model number (i.e., A9000U)

Features:

  • Compact
  • Easy installation
  • Eliminates welding to pipe
  • Overlapping galvanized sheet metal jacket
  • Minimizes heat-loss and/or condensation
  • Insulating structural inserts for load transfer
  • Copper tubing available
  • Other I.D.’s and/or O.D.’s available on request

Performance test results on file:
Available upon request

Material Data:

  • A9000:
    Applicable PSI spec. doc.: No. 205
  • Insulation:
    Calcium silicate asbestos-free,
    treated with water repellant
  • Jackets:
    Galvanized steel ASTM A-653
  • Structural Inserts: High-density calcium
    silicate asbestos-free, treated with water
    repellant
  • Glue:
    Industrial contact adhesive


Formal submittal sheets available

Top