ISO 9001 Certified

Insulated Friction Pipe Anchor

C3200

Load Rating400–18,600 lbs
Pipe Sizes½" – 42" IPS

Talk to a pipe support specialist about your application.

1-707-447-5014

General Dimensions & Specifications


Model C3200 Insulated Friction Pipe Anchor

Base Mounted.
C3200 dimensional drawing

The load ratings represent average values obtained in accordance with accepted
test methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thicknesses.

Note: For higher load ratings, see C3300, C4200.

Pipe
Size
Load Rating (lbs) Insulation Thickness
Vert. Lat. Axial 1″ 1 1/2″ 2″ 2 1/2″ 3″ 4″ 5″
B C E B C E B C E B C E B C E B C E B C E
1/2 400 200 80 4 1.5 3.25 4 2 4.375 4 2.5 5.375 4 4 7 6 4.5 8 6 6.5 10 8 8 12.125
3/4 500 250 100 4 1.5 3.25 4 2 4.375 4 2.5 5.375 4 4 7 6 4.5 8 6 6.5 10 8 8 12.25
1 650 325 130 4 2 4 4 2.5 5 4 3 6.062 4 4 7.125 6 4.5 8.125 6 6.5 10.125 8 8 12.25
1 1/2 950 475 190 4 2 4.5 4 2.5 5.5 4 4 7.125 4 4.5 8.125 6 5.5 9.125 6 7.5 11.25 8 9 13.25
2 1100 550 220 4 2.5 5 4 3 6.1875 4 4 7.125 4 4.5 8.125 6 5.5 9.125 6 7.5 11.25 8 9 13.25
2 1/2 1350 675 270 4 2.5 5.5 4 4 7.125 4 4.5 8.125 4 5.5 9.125 6 6.5 10.125 6 8 12.25 8 9.5 14.5
3 1600 800 320 4 3 6.187 4 4 7.125 4 4.5 8.125 4 5.5 9.125 6 6.5 10.125 6 8 12.375 8 9.5 14.625
4 2500 1250 500 4 4 7.25 4 4.5 8.25 4 5.5 9.25 4 6.5 10.25 6 7.5 11.375 6 9 13.375 8 10.5 15.625
5 3100 1550 620 4 4.5 8.5 4 5.5 9.5 4 6.5 10.5 4 7.5 11.625 6 8 12.625 6 9.5 14.875 8 11 16.875
6 3800 1900 760 4 5.5 9.5 4 6.5 10.5 4 7.5 11.625 4 8 12.625 6 9 13.625 6 10.5 15.875 8 12 17.875
8 5100 2550 1020 4 7.5 11.625 4 8 12.625 4 9 13.625 6 9.5 14.875 6 10.5 15.875 6 12 18.125 8 13 20.125
10 6000 3000 1200 4 9 13.875 4 9.5 15.125 4 10.5 16.125 6 11 17.125 6 12 18.125 6 13 20.125 8 14.5 22.125
12 6600 3300 1320 4 10.5 16.125 4 11 17.125 4 12 18.125 6 12.5 19.125 6 13 20.125 6 14.5 22.125 8 16 24.125
14 7500 3750 1500 4 11 17.125 4 12 18.125 4 12.5 19.125 6 13 20.125 6 14 21.125 6 15.5 23.125 8 16.5 25.125
16 8700 4350 1740 4 12.5 19.375 4 13 20.375 6 14 21.375 6 14.5 22.375 6 15.5 23.375 8 16.5 25.375 8 18 27.375
18 9600 4800 1920 4 14 21.375 4 14.5 22.375 6 15.5 23.375 6 16 24.375 6 16.5 25.375 8 18 27.375 8 19.5 29.375
20 10200 5100 2040 4 15.5 23.375 4 16 24.375 6 16.5 25.375 6 17.5 26.375 6 18 27.375 8 19.5 29.375 8 21 31.375
24 10800 5400 2160 4 18 27.375 4 19 28.375 6 19.5 29.375 6 20.5 30.375 6 21 31.375 8 22.5 33.375 8 24 35.375
30 14100 7050 2820 4 22.5 33.625 6 23 34.625 6 24 35.625 6 24.5 36.625 6 25 37.625 8 26.5 39.625 8 28 41.625
36 16500 8250 3300 4 26.5 40.125 6 27.5 41.125 6 28 42.125 6 28.5 43.125 6 29.5 44.125 8 31 46.125 8 32.5 48.125
42 18600 9300 3720 4 31 46.125 6 31.5 47.125 6 32.5 48.125 6 33 49.125 6 33.5 50.125 8 35 52.125 8 36.5 54.125
All dimensions in inches. “B”, “C” and “E” refer to the drawing above.

Application

Model C3200 is designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Where thermal cycles are infrequent
  • Steam
  • Air
  • Gas
  • Vacuum
  • Where axial forces are relatively light or in balance

Intended for installation on:

  • Flat surfaces

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., C3200U)

Features

  • All pipe sizes
  • Eliminates welding to pipe
  • Insulating structural inserts for load transfer
  • Bottom-of-pipe to top-of-steel matches insulated supports in “B” series
  • Easy installation
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
Performance test results on file – available upon request.

Material Data

C3200 Spec Doc Applicable PSI spec. doc.: No. 209
Insulation Calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Glue Industrial contact adhesive
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Steel Straps / Base Carbon steel, ASTM A-36
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model C3200U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Installation Guide

Installation Model A1000 - A4000 & A9000

Model A1000 – A4000 & A9000

1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.

2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.

Installation Model A5000 - A8400

Model A5000 – A8400

1. When used on a flat surface, position shield so that it is centered on the structural steel.

2. When used with a clevis hanger, position shield symmetrically.

3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.

Completed assembly without load plate

Completed Assembly Without Load Plate

Completed assembly with load plate

Completed Assembly With Load Plate

Downloads & resources

Form
Custom Design Request

Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.

Start Request →