ISO 9001 Certified

Insulated Positive Pipe Anchor

C4100

Load Rating400–12,400 lbs
Pipe Sizes½" – 42" IPS

Talk to a pipe support specialist about your application.

1-707-447-5014

General Dimensions & Specifications


Model C4100 Insulated Positive Pipe Anchor

Models C4100, C4110, C4120, C4130. Base Mounted.
C4100 dimensional drawing

The load ratings represent average values obtained in accordance with accepted
test methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thicknesses.

If thrust plate thickness “D” is greater than pipe wall thickness, consult factory.

Note: For higher load ratings, see C4200.

Pipe
Size
Load Rating (lbs) Insulation Thickness
Vert. Lat. Axial 1 1/2″ 2″ 2 1/2″ 3″ 4″
B C D E B C D E B C D E B C D E B C D E
1 400 200 640 4 2.5 0.25 5.375 4 3 0.25 6.437 4 4 0.25 7.5 6 4.5 0.25 8.5 6 6.5 0.3125 10.5
1 1/2 580 290 930 4 2.5 0.25 5.875 4 4 0.25 7.5 4 4.5 0.3125 8.5 6 5.5 0.3125 9.5 6 7.5 0.3125 11.625
2 720 360 1160 4 3 0.25 6.4375 4 4 0.25 7.5 4 4.5 0.3125 8.5 6 5.5 0.3125 9.5 6 7.5 0.3125 11.625
2 1/2 870 435 1410 4 4 0.25 7.5 4 4.5 0.25 8.5 4 5.5 0.3125 9.5 6 6.5 0.3125 10.5 6 8 0.375 12.625
3 1060 530 2400 4 4 0.3125 7.5 4 4.5 0.3125 8.5 4 5.5 0.375 9.5 6 6.5 0.375 10.5 6 8 0.5 12.625
4 1680 840 2900 4 4.5 0.3125 8.5 4 5.5 0.3125 9.5 4 6.5 0.375 10.5 6 7.5 0.375 11.625 6 9 0.5 13.625
5 2100 1050 3400 4 5.5 0.3125 9.5 4 6.5 0.3125 10.5 4 7.5 0.375 11.625 6 8 0.375 12.625 6 9.5 0.5 14.875
6 2550 1275 3900 4 6.5 0.3125 10.5 4 7.5 0.3125 11.625 4 8 0.375 12.625 6 9 0.375 13.625 6 10.5 0.5 15.875
8 3400 1700 4850 4 8 0.3125 12.625 4 9 0.3125 13.625 6 9.5 0.375 14.875 6 10.5 0.375 15.875 6 12 0.5 17.875
10 4000 2000 5850 4 9.5 0.3125 15.125 4 10.5 0.3125 16.125 6 11 0.375 17.125 6 12 0.375 18.125 6 13 0.5 20.125
12 4400 2200 6800 4 11 0.3125 17.125 4 12 0.3125 18.125 6 12.5 0.375 19.125 6 13 0.375 20.125 6 14.5 0.5 22.125
14 5000 2500 7350 4 12 0.3125 18.125 4 12.5 0.3125 19.125 6 13 0.375 20.125 6 14 0.375 21.125 6 15.5 0.5 23.125
16 5800 2900 8320 4 13 0.3125 20.125 6 14 0.3125 21.125 6 14.5 0.375 22.125 6 15.5 0.375 23.125 8 16.5 0.5 25.125
18 6400 3200 9240 4 14.5 0.3125 22.125 6 15.5 0.3125 23.125 6 16 0.375 24.125 6 16.5 0.375 25.125 8 18 0.5 27.125
20 6800 3400 10200 4 16 0.3125 24.125 6 16.5 0.3125 25.125 6 17.5 0.375 26.125 6 18 0.375 27.125 8 19.5 0.5 29.125
24 7200 3600 12000 4 19 0.3125 28.125 6 19.5 0.3125 29.125 6 20.5 0.375 30.125 6 21 0.375 31.125 8 22.5 0.5 33.125
30 9400 4700 14900 6 23 0.3125 34.375 6 24 0.3125 35.375 6 24.5 0.375 36.375 6 25 0.375 37.375 8 26.5 0.5 39.375
36 11000 5500 17750 6 27.5 0.3125 40.375 6 28 0.3125 41.375 6 28.5 0.375 42.375 6 29.5 0.375 43.375 8 31 0.5 45.375
42 12400 6200 20500 6 31.5 0.3125 46.375 6 32.5 0.3125 47.375 6 33 0.375 48.375 6 33.5 0.375 49.375 8 35 0.5 51.375
All dimensions in inches. “B”, “C”, “D” and “E” refer to the drawing above.

Application

Models C4100 through C4130 are designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Where large axial forces must be resisted
  • Steam
  • Air
  • Gas
  • Vacuum

Intended for installation on:

  • Flat surfaces

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., C4100U)

Features

  • All pipe sizes
  • Insulating structural inserts for load transfer
  • Bottom-of-pipe to top-of-steel matches insulated supports in “B” series
  • Easy installation
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
Performance test results on file – available upon request.

Material Data

C4100 – C4130 Spec Doc Specification document: No. 209
Thrust Plates Steel inner thrust plates (supplied loose):
C4100: ASTM A36, for Carbon Steel pipe
C4110: ASTM A387 Gr. 22, for Chrome-Moly pipe
C4120: ASTM A515 Gr. 70, for Carbon Silicon pipe
C4130: ASTM A304L, for Stainless Steel pipe
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Steel Straps & Base Carbon steel, ASTM A-36
Glue Industrial contact adhesive
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model C4100U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Installation Guide

Installation Model A1000 - A4000 & A9000

Model A1000 – A4000 & A9000

1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.

2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.

Installation Model A5000 - A8400

Model A5000 – A8400

1. When used on a flat surface, position shield so that it is centered on the structural steel.

2. When used with a clevis hanger, position shield symmetrically.

3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.

Completed assembly without load plate

Completed Assembly Without Load Plate

Completed assembly with load plate

Completed Assembly With Load Plate

Downloads & resources

Form
Custom Design Request

Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.

Start Request →
RFA
Revit RFA 3D Model

A1000 Insulated Pipe Support Revit RFA model for BIM & coordination workflows.

Download 3D Model →
Meet
Schedule a Meeting

Talk through your application with a Pipe Shields engineer.

Book a Time →