Hardware sold separately. Cross-section & dimension callouts shown in the technical data below.
Insulated Positive Pipe Anchor
C4100
Talk to a pipe support specialist about your application.
1-707-447-5014General Dimensions & Specifications
The load ratings represent average values obtained in accordance with accepted
test methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.
Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thicknesses.
If thrust plate thickness “D” is greater than pipe wall thickness, consult factory.
Note: For higher load ratings, see C4200.
| Pipe Size |
Load Rating (lbs) | Insulation Thickness | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Vert. | Lat. | Axial | 1 1/2″ | 2″ | 2 1/2″ | 3″ | 4″ | ||||||||||||||||
| B | C | D | E | B | C | D | E | B | C | D | E | B | C | D | E | B | C | D | E | ||||
| 1 | 400 | 200 | 640 | 4 | 2.5 | 0.25 | 5.375 | 4 | 3 | 0.25 | 6.437 | 4 | 4 | 0.25 | 7.5 | 6 | 4.5 | 0.25 | 8.5 | 6 | 6.5 | 0.3125 | 10.5 |
| 1 1/2 | 580 | 290 | 930 | 4 | 2.5 | 0.25 | 5.875 | 4 | 4 | 0.25 | 7.5 | 4 | 4.5 | 0.3125 | 8.5 | 6 | 5.5 | 0.3125 | 9.5 | 6 | 7.5 | 0.3125 | 11.625 |
| 2 | 720 | 360 | 1160 | 4 | 3 | 0.25 | 6.4375 | 4 | 4 | 0.25 | 7.5 | 4 | 4.5 | 0.3125 | 8.5 | 6 | 5.5 | 0.3125 | 9.5 | 6 | 7.5 | 0.3125 | 11.625 |
| 2 1/2 | 870 | 435 | 1410 | 4 | 4 | 0.25 | 7.5 | 4 | 4.5 | 0.25 | 8.5 | 4 | 5.5 | 0.3125 | 9.5 | 6 | 6.5 | 0.3125 | 10.5 | 6 | 8 | 0.375 | 12.625 |
| 3 | 1060 | 530 | 2400 | 4 | 4 | 0.3125 | 7.5 | 4 | 4.5 | 0.3125 | 8.5 | 4 | 5.5 | 0.375 | 9.5 | 6 | 6.5 | 0.375 | 10.5 | 6 | 8 | 0.5 | 12.625 |
| 4 | 1680 | 840 | 2900 | 4 | 4.5 | 0.3125 | 8.5 | 4 | 5.5 | 0.3125 | 9.5 | 4 | 6.5 | 0.375 | 10.5 | 6 | 7.5 | 0.375 | 11.625 | 6 | 9 | 0.5 | 13.625 |
| 5 | 2100 | 1050 | 3400 | 4 | 5.5 | 0.3125 | 9.5 | 4 | 6.5 | 0.3125 | 10.5 | 4 | 7.5 | 0.375 | 11.625 | 6 | 8 | 0.375 | 12.625 | 6 | 9.5 | 0.5 | 14.875 |
| 6 | 2550 | 1275 | 3900 | 4 | 6.5 | 0.3125 | 10.5 | 4 | 7.5 | 0.3125 | 11.625 | 4 | 8 | 0.375 | 12.625 | 6 | 9 | 0.375 | 13.625 | 6 | 10.5 | 0.5 | 15.875 |
| 8 | 3400 | 1700 | 4850 | 4 | 8 | 0.3125 | 12.625 | 4 | 9 | 0.3125 | 13.625 | 6 | 9.5 | 0.375 | 14.875 | 6 | 10.5 | 0.375 | 15.875 | 6 | 12 | 0.5 | 17.875 |
| 10 | 4000 | 2000 | 5850 | 4 | 9.5 | 0.3125 | 15.125 | 4 | 10.5 | 0.3125 | 16.125 | 6 | 11 | 0.375 | 17.125 | 6 | 12 | 0.375 | 18.125 | 6 | 13 | 0.5 | 20.125 |
| 12 | 4400 | 2200 | 6800 | 4 | 11 | 0.3125 | 17.125 | 4 | 12 | 0.3125 | 18.125 | 6 | 12.5 | 0.375 | 19.125 | 6 | 13 | 0.375 | 20.125 | 6 | 14.5 | 0.5 | 22.125 |
| 14 | 5000 | 2500 | 7350 | 4 | 12 | 0.3125 | 18.125 | 4 | 12.5 | 0.3125 | 19.125 | 6 | 13 | 0.375 | 20.125 | 6 | 14 | 0.375 | 21.125 | 6 | 15.5 | 0.5 | 23.125 |
| 16 | 5800 | 2900 | 8320 | 4 | 13 | 0.3125 | 20.125 | 6 | 14 | 0.3125 | 21.125 | 6 | 14.5 | 0.375 | 22.125 | 6 | 15.5 | 0.375 | 23.125 | 8 | 16.5 | 0.5 | 25.125 |
| 18 | 6400 | 3200 | 9240 | 4 | 14.5 | 0.3125 | 22.125 | 6 | 15.5 | 0.3125 | 23.125 | 6 | 16 | 0.375 | 24.125 | 6 | 16.5 | 0.375 | 25.125 | 8 | 18 | 0.5 | 27.125 |
| 20 | 6800 | 3400 | 10200 | 4 | 16 | 0.3125 | 24.125 | 6 | 16.5 | 0.3125 | 25.125 | 6 | 17.5 | 0.375 | 26.125 | 6 | 18 | 0.375 | 27.125 | 8 | 19.5 | 0.5 | 29.125 |
| 24 | 7200 | 3600 | 12000 | 4 | 19 | 0.3125 | 28.125 | 6 | 19.5 | 0.3125 | 29.125 | 6 | 20.5 | 0.375 | 30.125 | 6 | 21 | 0.375 | 31.125 | 8 | 22.5 | 0.5 | 33.125 |
| 30 | 9400 | 4700 | 14900 | 6 | 23 | 0.3125 | 34.375 | 6 | 24 | 0.3125 | 35.375 | 6 | 24.5 | 0.375 | 36.375 | 6 | 25 | 0.375 | 37.375 | 8 | 26.5 | 0.5 | 39.375 |
| 36 | 11000 | 5500 | 17750 | 6 | 27.5 | 0.3125 | 40.375 | 6 | 28 | 0.3125 | 41.375 | 6 | 28.5 | 0.375 | 42.375 | 6 | 29.5 | 0.375 | 43.375 | 8 | 31 | 0.5 | 45.375 |
| 42 | 12400 | 6200 | 20500 | 6 | 31.5 | 0.3125 | 46.375 | 6 | 32.5 | 0.3125 | 47.375 | 6 | 33 | 0.375 | 48.375 | 6 | 33.5 | 0.375 | 49.375 | 8 | 35 | 0.5 | 51.375 |
| All dimensions in inches. “B”, “C”, “D” and “E” refer to the drawing above. | |||||||||||||||||||||||
Application
Models C4100 through C4130 are designed for use on:
- Hot water
- Cold water
- Chilled water
- Dual temperature
- Where large axial forces must be resisted
- Steam
- Air
- Gas
- Vacuum
Intended for installation on:
- Flat surfaces
Temperature Range
Standard: +40°F to +1200°F CalSil Insulation
Note: Up to 1800°F available upon request.
Cryogenic: -275°F to +275°F Urethane Insulation.
Add U after the model number (i.e., C4100U)
Features
- All pipe sizes
- Insulating structural inserts for load transfer
- Bottom-of-pipe to top-of-steel matches insulated supports in “B” series
- Easy installation
- Overlapping galvanized sheet metal jacket
- Other I.D.’s and/or O.D.’s available on request
Material Data
| C4100 – C4130 Spec Doc | Specification document: No. 209 |
|---|---|
| Thrust Plates | Steel inner thrust plates (supplied loose): C4100: ASTM A36, for Carbon Steel pipe C4110: ASTM A387 Gr. 22, for Chrome-Moly pipe C4120: ASTM A515 Gr. 70, for Carbon Silicon pipe C4130: ASTM A304L, for Stainless Steel pipe |
| Structural Inserts | High-density calcium silicate, asbestos-free, treated with water repellant |
| Jackets | Galvanized steel, ASTM A-653 |
| Steel Straps & Base | Carbon steel, ASTM A-36 |
| Glue | Industrial contact adhesive |
| Fasteners | ASTM A-307, plated |
| Coating | Primer coated or hot dipped galvanized. Other coatings available upon request. |
| Cryogenic Insulation | Urethane (for -275°F to +275°F service, model C4100U) |
Need a formal submittal?
Formal submittal sheets are available.
Installation Guide
Model A1000 – A4000 & A9000
1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.
2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.
Model A5000 – A8400
1. When used on a flat surface, position shield so that it is centered on the structural steel.
2. When used with a clevis hanger, position shield symmetrically.
3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.
Completed Assembly Without Load Plate
Completed Assembly With Load Plate
Downloads & resources
Custom Design Request
Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.
Start Request →Revit RFA 3D Model
A1000 Insulated Pipe Support Revit RFA model for BIM & coordination workflows.
Download 3D Model →