ISO 9001 Certified

Insulated Positive Pipe Anchor

C4000

Load Rating200–6,200 lbs
Pipe Sizes1" – 42" IPS

Talk to a pipe support specialist about your application.

1-707-447-5014

General Dimensions & Specifications


Model C4000 Insulated Positive Pipe Anchor

Models C4000, C4010, C4020, C4030. Base Mounted.
C4000 dimensional drawing

The load ratings represent average values obtained in accordance with accepted
test methods and are subject to normal manufacturing variations. Dimensions and
ratings are subject to change without notice.

Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thicknesses.

If thrust plate thickness “D” is greater than pipe wall thickness, consult factory.

Note: For higher load ratings, see C4100.

Pipe
Size
Load Rating (lbs) Insulation Thickness
Vert. Lat. Axial 1″ 1 1/2″ 2″ 2 1/2″ 3″ 4″
B C D E B C D E B C D E B C D E B C D E B C D E
1 200 100 410 4 2 0.1875 4.125 4 2.5 0.1875 5.125 4 3 0.25 6.187 4 4 0.25 7.25 6 4.5 0.25 8.25 6 6.5 0.25 10.25
1 1/2 290 145 590 4 2 0.1875 4.625 4 2.5 0.1875 5.625 4 4 0.25 7.25 4 4.5 0.25 8.25 6 5.5 0.25 9.25 6 7.5 0.25 11.375
2 360 180 730 4 2.5 0.1875 5.125 4 3 0.1875 6.1875 4 4 0.25 7.25 4 4.5 0.25 8.25 6 5.5 0.25 9.25 6 7.5 0.3125 11.375
2 1/2 440 220 890 4 2.5 0.1875 5.625 4 4 0.1875 7.25 4 4.5 0.25 8.25 4 5.5 0.25 9.25 6 6.5 0.25 10.25 6 8 0.3125 12.375
3 530 265 1400 4 3 0.1875 6.187 4 4 0.25 7.25 4 4.5 0.25 8.25 4 5.5 0.3125 9.25 6 6.5 0.3125 10.25 6 8 0.375 12.375
4 840 420 1730 4 4 0.1875 7.25 4 4.5 0.25 8.25 4 5.5 0.25 9.25 4 6.5 0.3125 10.25 6 7.5 0.3125 11.375 6 9 0.375 13.375
5 1050 525 2060 4 4.5 0.1875 8.25 4 5.5 0.25 9.25 4 6.5 0.25 10.25 4 7.5 0.3125 11.375 6 8 0.3125 12.375 6 9.5 0.375 14.625
6 1275 638 2400 4 5.5 0.1875 9.25 4 6.5 0.25 10.25 4 7.5 0.25 11.375 4 8 0.3125 12.375 6 9 0.3125 13.375 6 10.5 0.375 15.625
8 1700 850 3020 4 7.5 0.1875 11.375 4 8 0.25 12.375 4 9 0.25 13.375 6 9.5 0.3125 14.625 6 10.5 0.3125 15.625 6 12 0.375 17.625
10 2000 1000 3700 4 9 0.1875 13.625 4 9.5 0.25 14.875 4 10.5 0.25 15.875 6 11 0.3125 16.875 6 12 0.3125 17.875 6 13 0.375 19.875
12 2200 1100 4320 4 10.5 0.1875 15.625 4 11 0.25 16.875 4 12 0.25 17.875 6 12.5 0.3125 18.875 6 13 0.3125 19.875 6 14.5 0.375 21.875
14 2500 1250 4700 4 11 0.1875 16.625 4 12 0.25 17.875 4 12.5 0.25 18.875 6 13 0.3125 19.875 6 14 0.3125 20.875 6 15.5 0.375 22.875
16 2900 1450 5340 4 12.5 0.1875 18.625 4 13 0.25 19.875 6 14 0.25 20.875 6 14.5 0.3125 21.875 6 15.5 0.3125 22.875 8 16.5 0.375 24.875
18 3200 1600 5970 4 14 0.1875 20.625 4 14.5 0.25 21.875 6 15.5 0.25 22.875 6 16 0.3125 23.875 6 16.5 0.3125 24.875 8 18 0.375 26.875
20 3400 1700 6600 4 15.5 0.1875 22.625 4 16 0.25 23.875 6 16.5 0.25 24.875 6 17.5 0.3125 25.875 6 18 0.3125 26.875 8 19.5 0.375 28.875
24 3600 1800 7850 4 18 0.1875 26.625 4 19 0.25 27.875 6 19.5 0.25 28.875 6 20.5 0.3125 29.875 6 21 0.3125 30.875 8 22.5 0.375 32.875
30 4700 2350 9740 4 22.5 0.1875 33.125 6 23 0.25 34.125 6 24 0.25 35.125 6 24.5 0.3125 36.125 6 25 0.3125 37.125 8 26.5 0.375 39.125
36 5500 2750 11600 4 26.5 0.1875 39.125 6 27.5 0.25 40.125 6 28 0.25 41.125 6 28.5 0.3125 42.125 6 29.5 0.3125 43.125 8 31 0.375 45.125
42 6200 3100 13500 4 31 0.1875 45.125 6 31.5 0.25 46.125 6 32.5 0.25 47.125 6 33 0.3125 48.125 6 33.5 0.3125 49.125 8 35 0.375 51.125
All dimensions in inches. “B”, “C”, “D” and “E” refer to the drawing above.

Application

Models C4000 through C4030 are designed for use on:

  • Hot water
  • Cold water
  • Chilled water
  • Dual temperature
  • Where large axial forces must be resisted
  • Steam
  • Air
  • Gas
  • Vacuum

Intended for installation on:

  • Flat surfaces

Temperature Range

Standard: +40°F to +1200°F CalSil Insulation

Note: Up to 1800°F available upon request.

Cryogenic: -275°F to +275°F Urethane Insulation.

Add U after the model number (i.e., C4000U)

Features

  • All pipe sizes
  • Insulating structural inserts for load transfer
  • Bottom-of-pipe to top-of-steel matches insulated supports in “B” series
  • Easy installation
  • Overlapping galvanized sheet metal jacket
  • Other I.D.’s and/or O.D.’s available on request
Performance test results on file – available upon request.

Material Data

C4000 – C4030 Spec Doc Specification document: No. 209
Thrust Plates Steel inner thrust plates (supplied loose):
C4000: ASTM A36, for Carbon Steel pipe
C4010: ASTM A387 Gr. 22, for Chrome-Moly pipe
C4020: ASTM A515 Gr. 70, for Carbon Silicon pipe
C4030: ASTM A304L, for Stainless Steel pipe
Structural Inserts High-density calcium silicate, asbestos-free, treated with water repellant
Jackets Galvanized steel, ASTM A-653
Steel Straps & Base Carbon steel, ASTM A-36
Glue Industrial contact adhesive
Fasteners ASTM A-307, plated
Coating Primer coated or hot dipped galvanized. Other coatings available upon request.
Cryogenic Insulation Urethane (for -275°F to +275°F service, model C4000U)

Need a formal submittal?

Formal submittal sheets are available.

Request a Quote
Custom Design Request

Installation Guide

Installation Model A1000 - A4000 & A9000

Model A1000 – A4000 & A9000

1. Position the bottom half of the insulated hanger shield (insulating structural material, sheet metal jacket and load plate where applicable) on the pipe at the applicable support location as shown.

2. Hold the top half of the shield firmly. Open the overlapping sheet metal jacket and gently slide into position the top half of the insulated shield over the bottom half shield as shown.

Installation Model A5000 - A8400

Model A5000 – A8400

1. When used on a flat surface, position shield so that it is centered on the structural steel.

2. When used with a clevis hanger, position shield symmetrically.

3. When models include heat trace groves, the number and location may vary. Check with design drawings for exact number and location. Ensure that the heat tracing cable is properly positioned inside the grove of the shield.

Completed assembly without load plate

Completed Assembly Without Load Plate

Completed assembly with load plate

Completed Assembly With Load Plate

Downloads & resources

Form
Custom Design Request

Need other I.D.'s, O.D.'s, temperatures or loads? Submit a custom design request.

Start Request →
RFA
Revit RFA 3D Model

A1000 Insulated Pipe Support Revit RFA model for BIM & coordination workflows.

Download 3D Model →
Meet
Schedule a Meeting

Talk through your application with a Pipe Shields engineer.

Book a Time →
Top