Pipe Shields Model A1000 - Insulated Pipe Support - Regular Duty
Download PDF Download PDF

A1000 Insulated Pipe Shoe
Oper. Temp°F
Mult. Factor "F"
500
750
1000
1200
.90
.75
.50
.30
Table III

Hardware Sold Separately - Note: For higher load ratings, see A3000, A9000. The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice.

To develop maximum load rating, width of support surface should be at least 1/2 of dimension "A" in Table II. To develop maximum load rating, use band, ring or clevis hanger with manufacturer's load rating equal to or greater than values shown in Table I.

To obtain load ratings for operating temperatures of 500°F and higher, multiply load rating by factor "F" in Table III.

Installation Instructions

Pipe Size
Maximum Load Rating (lb.)
On Flat Surface (a) (c)

In Clevis Hanger (b) (c)

1/2
3/4
1
35
40
60
40
45
65
1 1/4
1 1/2
2
70
100
125
80
110
140
2 1/2
3
3 1/2
150
180
225
200
250
300
4
5
6
270
350
400
350
450
550
8
10
12
450
500
550
750
1000
1200
14
16
18
575
600
625
1400
1600
1800
20
24
675
750
2000
2300
TABLE I
Iron Pipe Size
Insulation Thickness
Copper Tubing Size O.D.
1/2
3/4
1
1 1/2
2
2 1/2
3
3 1/2
4
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
1/2 - 1 1/2
4
24
4
24
4
24
4
24
4
24
4
24
6
24
6
24
6
24
5/8 - 1 5/8
2
6
24
6
24
6
24
6
24
6
24
6
24
6
24
6
24
6
24
2 1/8
2 1/2 - 4
6
20
6
20
6
20
6
20
6
20
6
20
9
20
9
20
9
20
2 5/8 - 4 1/8
5
6
20
6
20
6
20
6
20
9
20
9
20
9
20
5 1/8
6 - 7
6
20
6
20
6
20
6
20
9
16
9
16
9
16
6 1/8
8 - 10
9
16
9
16
9
16
9
16
9
16
9
16
8 1/8 - 10 1/8
12 - 18
12
16
12
16
12
16
12
16
12
16
12
16
12 1/8
20 - 24
18
16
18
16
18
16
18
16
18
16
18
16
TABLE II "B" = gauge of sheet metal jacket

Application:

Model A1000 is designed for use on:

  • Hot Water
  • Cold Water
  • Dual Temperature
  • Vacuum
  • Steam
  • Chilled Water
  • Gas
  • Air

Intended for Installation on:

  • Flat Surfaces
  • Band, ring or clevis pipe hanger

Temperature Range: +40°F to +1200°F

Note: Up to 1700°F available upon request.

Features

  • Compact
  • Easy Installation
  • Eliminates welding to pipe
  • Overlapping galvanized sheet metal jacket
  • Minimizes heat loss and/or condensation
  • Copper tubing sizes available
  • Other I.D.'s and/or O.D.'s available on request
  • Clamps available (see G-Series)

Performance Test Results on File: Available upon request.

Material Data:

  • A1000: Applicable PSI spec. doc.: No. 205
  • Insulation: Calcium Silicate asbestos-free, treated with water repellant.
  • Jackets: Galvanized Steel ASTMA-527
  • Glue: Industrial contact adhesive

Formal Submittal Sheets Available

 

 

 

 

Parent Company: Piping Technology: Pipe Supports, Pipe Clamps, & Pipe Hardware
Fellow Subsidiaries
U.S. Bellows: Metallic & Fabric Expansion Joints, Bellows
Sweco Fab: ASME Vessels, Pig Launchers, Spectacle Blinds

Pipe Shields: Pre-Insulated Pipe Supports, Slides, Guides & Anchors
Fronek Anchor/Darling
: Snubbers, Sway Struts & Sway Braces
Contact Us: 707-447-5014 Toll Free1-800-538-7007. info@pipeshields.com

Copyright 2018 Pipe Shields, Inc. All Rights Reserved. Contact Us | Privacy Policy